GPIO_SET_PLS_CNT_CFG (0x1D)

The GPIO_SET_PLS_CNT_CFG command allows to configure pulse counter module, to start, stop and suspend pulse counting and to set the conditions of the event generation.

GPIO_SET_PLS_CNT_CFG Command

Go to Response

Byte 0 GPIO_SET_PLS_CNT_CFG Command ID (must be 0x1D).
Byte 1 ECHO Echo to associate the command with the response.
Byte 2 Bits 7..3 Reserved Reserved (must be 0).
Bit 2 SUSPENDED Pulse counter state (suspended or not).
Bit 1 ON Pulse counter switcher (used to start/stop pulse counting).
Bit 0 PLS_CNT_NUMBER ID number of the counter to count pulses.
Byte 3 Bits 7..4 PLS_CNT_MODE Pulse counter mode.
Bit 3 Reserved Reserved (must be 0).
Bit 2 EV_MATCH Matcher (an event will be sent when counter limits are exceeded).
Bit 1 Reserved Reserved (must be 0).
Bit 0 EV_OVERFLOW Matcher (an event will be sent when maximum number of pulses is detected).
Byte 4 REPEAT Repeat interval value in units of 10 ms.
Byte 5 LIMIT[2] Counter limit (time period or threshold number of pulses).
Byte 6 LIMIT[1]
Byte 7 LIMIT[0]

Command is an 8-byte array of the following format:

Byte 0: GPIO_SET_PLS_CNT_CFG (0x1D)

This byte contains command ID (command type). It must be set to 0x1D.

Byte 1: ECHO

This byte is used to associate a response received from GPIO-24 adapter with a specific command. Response will contain exactly the same value in its echo byte.

Byte 2:
Bits 7..3 Bit 2 Bit 1 Bit 0
Reserved SUSPENDED ON PLS_CNT_NUMBER
Bits 7..3: Reserved

These bits are reserved for future usage. They must be set to 0.

Bit 2: SUSPENDED

Pulse counter state:

  • 0 – pulse counter runs immediately after configuration.

  • 1 – pulse counter will be in suspended state. It will not run until you send the GPIO_RESUME_PLS_CNT command.

 

Bit 1: ON

The pulse counter state (on/off):

  • 1 – the pin is switched to the pulse counter mode. GPIO_GET_CFG and GPIO_GET_PIN_CFG commands will return GPIO_CFG_PLS_CNT (0x7) value for the pin. The pin can be used only by the pulse counter module;

  • 0 – the pulse counter mode is switched off on the pin. GPIO_GET_CFG and GPIO_GET_PIN_CFG commands will return GPIO_CFG_NOT_CONFIGURED (0xf)value for the pin. The pin can be used by any module.

 

Bit 0: PLS_CNT_NUMBER

The ID number of the pulse counter:

  • 0 – pulse counter on A.3 pin;

  • 1 – pulse counter on A.4 pin.

 

Byte 3:
Bits 7..4 Bit 3 Bit 2 Bit 1 Bit 0
PLS_CNT_MODE Reserved EV_MATCH Reserved EV_OVERFLOW
Bits 7..4: PLS_CNT_MODE

The pulse counter can be configured into one of three possible modes:

  • GPIO_PLS_CNT_MODE_FREE_RUN(0) – pulses are counted until maximum number of pulses (16,777,215) is reached. For more detailed information seeSection 11.1.1, “Free Run Mode”.

  • GPIO_PLS_CNT_MODE_TIME_BASED(1) – pulses are counted only during user-defined time period. For more detailed information see Section 11.1.2, “Time Based Mode”.

  • GPIO_PLS_CNT_MODE_PULSE_BASED(2) – pulses are counted until user-defined number of pulses is detected. For more detailed information seeSection 11.1.3, “Pulse Based Mode”.

 

Bit 3: Reserved

This bit is reserved for future usage. It must be set to 0.

Bit 2: EV_MATCH
  • 1 – USB-I/O adapter will send the GPIO_EV_PLS_CNT event either when the time period is exceeded (Time Based Mode) or when the threshold number of pulses is detected (Pulse Based Mode). For more detailed information see Section 11.2, “Pulse Counter Event”;

  • 0 – the event is not generated when pulse counter limits are reached.

This bit is not used in Free Run Mode and must be set to 0.

Bit 1: Reserved

This bit is reserved for future usage and must be set to 0.

Bit 0: EV_OVERFLOW
  • 1 – USB-I/O adapter will send the GPIO_EV_PLS_CNT event when maximum number of pulses is reached. For more detailed information see Section 11.2, “Pulse Counter Event”;

  • 0 – the event is not generated when maximum number of pulses is reached.

Byte 4: REPEAT

This byte defines the repeat interval for GPIO_EV_PLS_CNT event generation. If this byte is non-zero, GPIO-24 adapter sends events each REPEAT*10 ms. For more detailed information see Section 11.2, “Pulse Counter Event”.

Bytes 5..7: LIMIT

These bytes define pulse counter limits.

For the pulse counter in Time Based Mode these bytes define the time period in units of 10 ms up to 16,777,215 (167,772,150 ms or 46.5 h). Pulses will be counted only during this time period.

For the pulse counter in Pulse Based Mode these bytes define the threshold number of pulses up to 16,777,215. Pulses will be counted until this number is detected.

Byte 5: LIMIT[2] – least significant byte (low byte) of a pulse counter limit.

Byte 6: LIMIT[1] – middle byte of threshold a pulse counter limit.

Byte 7: LIMIT[0] – most significant byte (high byte) of a pulse counter limit.

For the pulse counter in Free Run Mode these bytes are not used and must be set to 0.

For convenience GPIO_SET_PLS_CNT_CFG_CMD structure is declared in reports.h file.

GPIO-24 adapter sends GPIO_SET_PLS_CNT_CFG response after command execution.

GPIO_SET_PLS_CNT_CFG Response

Go to Command

Byte 0 GPIO_SET_PLS_CNT_CFG Response ID (0x1D).
Byte 1 ECHO Echo to associate command with the response.
Byte 2 ST Command execution status.
Bytes 3..7 Reserved Reserved.

Response is an 8-byte array of the following format:

Byte 0: GPIO_SET_PLS_CNT_CFG (0x1D)

Response ID (response type). This byte will contain 0x1D.

Byte 1: ECHO

Echo byte copied from the corresponding command. It is used to associate the response with the specific command.

Byte 2: ST

Status of the command execution:

  • GPIO_ST_SUCCESS (0x00) – Pulse counter has succesfully been configured;

  • GPIO_ST_INVALID_PARAMETER (0x0A) – Unsupported pulse counter mode has been specified.

 

Bytes 3..7: Reserved

These bytes are reserved for future usage.

For convenience GPIO_SET_PLS_CNT_CFG_RSP structure is declared in reports.h file.